2 ac operation – replacing fuses – Comtech EF Data CDD-562L User Manual

Page 54

Advertising
background image

CDD-562L/564 Demodulator with IP Module

Revision 2

Rear Panel Connections

MN/CDD564L.IOM

3–8

3.3.2.2 AC Operation – Replacing Fuses

The CDD-56X uses two 5mm x 20mm Slow-blow fuses – one each for line and neutral
connections. The fuses are contained within a fuse holder that is press-fit into the body of the IEC
power module (located on the rear panel, Figure 3-5).


 
 
 

 
 
 
 
 
 
 
 

Figure 3-5. Replacing CDD-56X AC Fuses

 
To replace the fuse(s):

DISCONNECT THE POWER SUPPLY BEFORE PROCEEDING! 

• First, unseat the fuse holder from the IEC power module.


o

Use the slot to pry the holder outward from the IEC power module.

o

Pull the holder straight out, and then swing the holder away from the module.

• Then, remove and replace the T3.15A (3.15 Amp) fuses as needed.


 

FOR  CONTINUED  OPERATOR  SAFETY,  ALWAYS  REPLACE  THE  FUSES  WITH  THE 
CORRECT TYPE AND RATING. 

• Finally, re-seat the fuse holder in the IEC power module.