3.3.2.2 AC Operation – Replacing Fuses

The CDD-56X uses two 5mm x 20mm Slow-blow fuses – one each for line and neutral
connections. The fuses are contained within a fuse holder that is press-fit into the body of the IEC
power module (located on the rear panel, Figure 3-5).


 
 
 

 
 
 
 
 
 
 
 

Figure 3-5. Replacing CDD-56X AC Fuses

 
To replace the fuse(s):

DISCONNECT THE POWER SUPPLY BEFORE PROCEEDING! 

First, unseat the fuse holder from the IEC power module.


o

Use the slot to pry the holder outward from the IEC power module.

o

Pull the holder straight out, and then swing the holder away from the module.

Then, remove and replace the T3.15A (3.15 Amp) fuses as needed.


 

FOR  CONTINUED  OPERATOR  SAFETY,  ALWAYS  REPLACE  THE  FUSES  WITH  THE 
CORRECT TYPE AND RATING. 

Finally, re-seat the fuse holder in the IEC power module.