Comtech EF Data CDD-562L User Manual

Page 174

Advertising
background image

CDD-562L/564 Demodulator with IP Module

Revision 2

HTTP (Web Server) Interface

MN/CDD564L.IOM

9–14

• Click Yes or No to Enable Authentication Trap.

• Assign the SNMP Trap IP Primary and Trap IP Secondary addresses.

• Use the drop-down list to set the Trap Version as SNMPv1 or SNMPv2.

Assign the SNMP Read, Write, and Trap Community Strings. Each Community String may
consist of a minimum of 0 to a maximum of 20 alphanumeric characters in length.

The factory defaults for these parameters are as follows:

o

Read Community String

public

o

Write Community String

private

o

Trap Communty String comtech

• Assign the SNMP Contact, SNMP Name, and SNMP Location.

Vipersat Management

For details on configuration and use of Vipersat operations via the HTTP
Interface, consult adjunct Comtech EF Data publication
MN/22137 – Vipersat
CDD-56X Series Satellite Network Demodulator Router User Guide


Click [Submit] to execute the changes made on this page.