CDD-562L/564 Demodulator with IP Module

Revision 2

Rear Panel Connections

MN/CDD564L.IOM

3–10

3.3.3.2 DC Operation – Replacing Fuses

The CDD-56X uses two 5mm x 20mm Slow-blow fuses – one each for line and neutral
connections. The fuses are contained within a fuse holder that is press-fit into the body of the DC
power module (located on the rear panel, Figure 3-8).
 
 
 
 
 

Feature

Description

1

Hinged Flap

2

Press-fit Fuse Holder

3

Fuse (2X)

 
 
 
 
 
 
 
 
 
 

Figure 3-8. Replacing CDD-56X DC Fuses

To replace the fuse(s):

DISCONNECT THE POWER SUPPLY BEFORE PROCEEDING!

• First, using a flat-bladed screwdriver, use the slot to pry open and swing back the

hinged flap.

• Next, extract the press-fit fuse holder:


o

Using the screwdriver, disengage the fuse holder outward from the DC power module.

o

Using your fingers, pull the holder straight out of the module.


• Then, remove and replace the T8A (8 Amp) fuses as needed.

 

FOR CONTINUED OPERATOR SAFETY, ALWAYS REPLACE THE FUSES WITH THE 
CORRECT TYPE AND RATING. 

• Finally, re-seat the fuse holder into the DC power module, and close the protective flap.