3.3.3.2 DC Operation – Replacing Fuses

The CDD-56X uses two 5mm x 20mm Slow-blow fuses – one each for line and neutral
connections. The fuses are contained within a fuse holder that is press-fit into the body of the DC
power module (located on the rear panel, Figure 3-8).
 
 
 
 
 

Feature

Description

1

Hinged Flap

2

Press-fit Fuse Holder

3

Fuse (2X)

 
 
 
 
 
 
 
 
 
 

Figure 3-8. Replacing CDD-56X DC Fuses

To replace the fuse(s):

DISCONNECT THE POWER SUPPLY BEFORE PROCEEDING!

First, using a flat-bladed screwdriver, use the slot to pry open and swing back the

hinged flap.

Next, extract the press-fit fuse holder:


o

Using the screwdriver, disengage the fuse holder outward from the DC power module.

o

Using your fingers, pull the holder straight out of the module.


Then, remove and replace the T8A (8 Amp) fuses as needed.

 

FOR CONTINUED OPERATOR SAFETY, ALWAYS REPLACE THE FUSES WITH THE 
CORRECT TYPE AND RATING. 

Finally, re-seat the fuse holder into the DC power module, and close the protective flap.