D–12

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Ping Reply Enabled PRE=

1 byte, value of
0 or 1

Command or Query.
Enables or disables ping reply, where:
0 = Disabled
1 = Enabled
Note: When disabled, the modem will not respond to pings (network security feature)

PRE =
PRE!

PRE?

PRE=x
(see Description of Arguments)

Enable/Disable QoS
Feature

QSE=

1 byte value
0 – Disable
1 – Enable

Command or Query.

Sets the Quality of Service feature, where:
0 = Disabled
1 = Enabled

QSE=
QSE!

QSE?

QSE=x

RX Header
Compression
enable/disable

RHE=

1 byte, value of
0, 1, 2 or 3

Command or Query.

Enables or disables the Transmit 3xDES feature, where,
0 = Disabled
1 = Enabled
Restriction: Cannot enable if the 3xDES FAST feature has not been purchased

RHE =
RHE!

RHE?

RHE =x
(see Description of Arguments)

ReadOnly
Password

ROP= 11

bytes

No spaces
allowed.

Command or Query.

Changes the ReadOnly password.
Example: ROP =comtech

ROP =
ROP!

ROP?

ROP=xxxxxxxxxxx
(see Description of Arguments)

ReadOnly
UserName

ROU=

11 bytes
No spaces
allowed.

Command or Query.

Changes the ReadOnly username.
Example: ROU=comtech
Note: To activate the new user name, ROP must be issued immediately after ROU.

ROU =
ROU!

ROU?

ROU=xxxxxxxxxx
(see Description of Arguments)

ReadWrite
Password

RWP=

11 bytes
No spaces
allowed.

Command or Query.

Changes the ReadWrite password.
Example: RWP=comtech

RWP =
RWP!

RWP?

RWP=xxxxxxxxxxx
(see Description of Arguments)

ReadWrite
UserName

RWU=

11 bytes
No spaces
allowed.

Command or Query.
Changes the ReadWrite username.
Example: RWU=comtech
Note: To activate the new user name, RWP must be issued immediately after RWU.

RWU =
RWU!

RWU?

RWU=xxxxxxxxxxx
(see Description of Arguments)

System
Configuration Get

None String

of

Variable byte
size

Query only.

Querying SCG? dumps the system configuration. This can be used for updating the GUI
parameters. See the Appendix section for more information on individual field.

SCG=
SCG!

SCG?

SCG=string of variable byte
size.

SMTP Domain
Name

SDM= 128

bytes,

characters, no
spaces

Command or Query.

SMTP Domain name of up to 128 characters.
Note: Entering an empty string will delete the domain name. To delete the domain name,
issue <1/SDM=
Example:
SMTP=somedomainname

SDM =
SDM!

SDM?

SDM=x [1..128]
(see Description of Arguments)

Advertising