2 maint | operations – Comtech EF Data CDD-562L User Manual

Page 198

Advertising
background image

CDD-562L/564 Demodulator with IP Module

Revision 2

HTTP (Web Server) Interface

MN/CDD564L.IOM

9–38

9.3.6.2 Maint | Operations

Use this page to configure the unit’s handling of firmware upon bootup.

Figure 9-29. Maint | Operations page

Boot/Upgrade Image

Boot From: Determines which firmware version (includes Application, FPGA, and FFPGA)

will be loaded upon bootup.

Use the drop-down list to select:

o

Latest – Boots the newest firmware load based upon date.

o

Image1 – Boots the firmware loaded into the first slot in permanent storage.

o

Image2 – Boots the firmware loaded into the second slot in permanent storage.

Upgrade To: Determines which installed firmware (includes Application, FPGA, and

FFPGA) that the demodulator will overwrite when upgrading with a new firmware download.

Use the drop-down list to select:

o

Oldest – Overwrites the oldest firmware based upon date.

o

Image1 – Overwrites the firmware loaded into the first slot in permanent storage.

o

Image2 – Overwrites the firmware loaded into the second slot in permanent storage.

Parameters Image

Operations: Use the drop-down list to select one of the following:

o

None – No deviation from the parameter currently saved to Flash.