1 ac operation – applying power – Comtech EF Data CDD-562L User Manual

Page 53

Advertising
background image

CDD-562L/564 Demodulator with IP Module

Revision 2

Rear Panel Connections

MN/CDD564L.IOM

3–7

3.3.2

100V/240V Alternating Current (AC) Power Interface (Standard)


Figure 3-3. CDD-56X AC Power Interface

3.3.2.1 AC Operation – Applying Power

 
 
 
 
 
 
 
 
 

Figure 3-4. Applying AC Power to the CDD-56X

 
To apply AC power to the CDD-56X (Figure 3-4):

First, plug the provided AC power cord female end into the unit.

Then, plug the AC power cord male end into the user-supplied power source.

Finally, switch the unit ON.

Feature

Description

1

On / Off Switch

2

Press-fit Fuse Holder

3

IEC Three-prong Connector

AC Power Specifications

Input Power

40W maximum, 20W typical

Input Voltage

100V to 240V AC, +6%/-10%, autosensing
(total absolute max. range is 90V to 254V AC)

Connector Type

IEC

Fuse Protection

Line and neutral fusing

(2X) 5mm x 20mm Slow-blow type fuses:

T3.15A (100V or 240V AC operation)