45

Logging in to the Web interface

You can use the following default settings to log in to the Web interface through HTTP:

Username—admin

Password—admin

IP address of VLAN-interface 1 of the device—192.168.0.100.

To log in to the device through HTTP:

1.

Connect the GigabitEthernet interface of the device to a PC by using a crossover Ethernet cable.
By default, all interfaces belong to VLAN 1.
The PC in this procedure is used for configuring basic device settings, and it is not necessarily the
PC you use for Web-based management.

2.

Configure an IP address for the PC and make sure the PC and device can reach each other.
For example, assign the PC an IP address 192.168.0.0/24 (excluding 192.168.0.100,

192.168.0.2 for example).

3.

Open the browser, and input the login information.

a.

In the address bar, type the IP address http://192.168.0.100, and press Enter.
The login page of the Web interface (see

Figure 17

) appears.

b.

Enter the username admin and password admin, and click Login.

Figure 17 Logging in to the Web interface

c.

Select a country/region code from the Country/Region list, and click Apply.

Advertising