Verifying the configuration, Client information backup configuration example, Network requirements – H3C Technologies H3C WX3000E Series Wireless Switches User Manual

Page 796

Advertising
background image

775

Figure 806 Backing up the IP address of AC 2

Verifying the configuration

1.

When AC 1 goes down, AC 3 becomes the new active AC.

2.

When AC 1 recovers, the AP connecting to AC 3 connects to AC 1 again. This is because the
highest AP connection priority of 7 on AC 1 ensures an automatic switchover.

Client information backup configuration example

Network requirements

As shown in

Figure 528

, AC 1 and AC 2 support stateful failover. AC 1 is the primary AC. Enable client

information backup on the two ACs so the clients can communicate during a primary/backup switchover.

The client in this example is a client that uses clear-type service template for accessing the network.

Figure 807 Network diagram

Advertising