Yaskawa i80M Connecting Manual User Manual

Page 133

Advertising
background image

20.2.3 MANUAL HANDLE/STEP MULTIPLICATION FACTOR (MP1 , MP2, MP4) INPUT

(# 30025, # 30026, # 30027)

When the control is in the manual handle/manual step feed mode, the motion distance per step

is determined by these input signals.

Table 20.3 Manual Handle/Step Multiplication Setting

20.2.4

M

PI

M

P2

M P4

Manual Step Feed

Manual Handle Feed

o

0

0

1

pulse/step

1

0

0

10 pulses/step

o

0

100 pulses/step

1

0

1000 pulses/step

100 pulses/step

o

0

10,000 pulses/step

100 pulses/step

1

0

1

100,000 pulses/step

100 pulses/step

o

1

Do not set.

1

1

1

1:

Closed, O:

O p e n

INPUT SIGNALS FOR CYCLE START (ST # 30030) AND STOP ( SP # 30031) : OUT-

PUT SIGNALS FOR CYCLE START (STL # 35370) AND FEEDHOLD (SPL # 35371)

(1) With the control in any of the TAPE, MEMORY, and MDI, EDT modes, when the input con-

tact ST is closed and opened, the control starts automatic operation control to execute the

part program, and at the same time, turn on the STL output signal for cycle start. However,

an ST input is disregarded under the following conditions.

While the control is in and alarm state. (While an alarm output or an input error output is

on. )

(b) While the feedhold

SP

input contact is open.

(c) While the external reset ERS input contact is closed.

(d) While the

RESET button on the

CRT panel is being depressed.

While the emergency stop ESP contact is not closed.

(f) While the STL signal output is being generated during automatic operations.

(2) When the following state is entered after cycle start, the control completes operation con-

trol, and turns off the STL output.

When a part program has been executed by manual data input in the MDI mode.

(b) When one block of a part program has been executed with the single block

input

contact closed.

(c) When the end of program

input contact has been closed by an M command of a

part program.

133