21. 3.2.3 OPTIONAL STOP INPUT (OPT #30406)

This input invalidates the MO1 command.
While the optional stop input is closed, the MO1 command is ignored.

21. 3.2.4 END-OF-PROGRAM INPUT (EOP # 30410), REWIND INPUT (RWD # 3041 1), AND

REWIND STATE OUTPUT

# 35376)

(1) End-of-program

and Rewind

Inputs

These inputs determine the procedure that the control performs at the end of M02/M30 com-

mand execution.

The control takes the actions indicated in Table 21. 14 depending on the EOP and RWD input
states prevailing when the completion input (FIN) relative to the M02/M30 command closes.

In general, the M02R output is connected to the EOP input, and the

is connected to the

RWD input.

Table 21.14 Relationship between the EOP/RWD Inputs and

Actions to Be Taken

EOP RWD

1

1

0

0

I

Actions to be taken

The control goes into standby mode after re-
winding part programs and resetting programs,
The control goes into standby mode after re-
setting programs,

The control goes into standby mode after re-
setting programs.

The control goes into standby mode after re-
winding part programs.

The control goes into standby mode,

1: Closed. O : open

NOTE

1. The above EOP/RWD function is the same as the program reset

function except that the reset procedure

key ON or

external reset

input closure) and NC memory rewinding procedure

are not performed.

For the details of the reset procedure, see under EXTERNAL RESET

INPUT

2. While the program reset function is being executed, the circuit be-
tween reset state outputs RST1 and RST2 is closed for one second.

Rewind State Output

This output indicates that the control is rewinding a part program.
While the RWD input is rewinding a part program in response to the M02/M30 command, the

RWDS output is generated.

NOTE

When using this input, set parameter RWDOUT (pm5000

) to 1. The

output is not generated if the parameter is set to O.