Yaskawa i80M Connecting Manual User Manual
Page 279

Table 21.
SPA, SPB, SPC, SPD, and SPE Inputs and S-command Override
SPA input SPB input SPC input SPD input SPE input
S-command override
o
0
0
1
0
10%
o
0
1
1
0
20%
—
o
-
1
1
1
0
30%
o
60%
o
70%
1
o
o
o
I
80%
o
90%
o
100%
150%
160%
170%
180%
0
0
0
0
1
190%
1
0
0
0
1
200 %
NOTE: 1: Closed. O:
21. 3.4.5
COMMAND EXTERNAL OUTPUTS
# 36540
# 36567) AND
COMMAND EXTERNAL INPUTS
#31120
#31147)
When the control uses the
command, the captioned
signals function so that the re-
sults of S command based part program computations are externally output, and that the actual
S5-digit command analog output complies with the external input.
command analog output)
(a) Computation result output to the outside:
(b) External input for transferring analog voltages out to the DAI and SG :
NOTE: Signed binary 23-bit
values are used.
The relationship between the values and
analog voltages is as follows.
–8388607
+8358607
–1OV
NOTE
The main objective of the above
signals
command from the control built-in sequencer.
do not use the signals for other purposes.
is to control the
Under normal conditions,
279