Yaskawa i80M Connecting Manual User Manual

Page 163

Advertising
background image

NOTE

The 200-540 % range is optionally available.

Feed Override Cancel (OVC #30407

This is the input for fixing the feedrate override at

When the OVC input contact is

closed, the feed rate in part program execution in the automatic operation modes is locked at

the programmed value, irrespective of the override input conditions.

20.2.46

BLOCK

D

E L E

TE (

BDT

#30405,

# 30420 -BDT9 #30427)

INPUT

This input is for determining whether data between “/” and

in a part program are ex-

ecuted or disregarded when the part program contains “/.”
The effective modes are MEM, TAPE, and MDI.

Table 20.16

1

Data between

BDT INPUT CLOSED

I “/”

or “/1”

and

(End of block)

BDT2 INPUT CLOSED

“/2”

and

BDT3

INPUT CLOSED

“/3”

and

BDT4

INPUT CLOSED

BDT5 INPUT CLOSED

“/5”

and

BDT6 INPUT CLOSED

“/6”

and

BDT7 INPUT CLOSED

BDT8 INPUT CLOSED

BDT9 INPUT CLOSED

“/9” and

“EOB”

Note :

1. Data can

disregarded only when part programs

executed,

When storing or processing part programs, this input has no effect.

2. Whether data may be disregarded or not depends on the state of

the optional block skip input relay when the block containing “/” in a

part program is stored in the buffer. Therefore, when controlling

the optional delete input relay by an external circuit with the use

the auxiliary function, take care to set the input state before the

block containing “/” is stored in the buffer.

3. If two or more

block delete inputs

provided for one

block, the following operation takes place.

Example) When the BDT3 input is closed

/GO1

/ 2

Significant information

Nonsignificant information

4. The optional block delete function does not work on

grams.

163