20.2.9 EXTERNAL RESET (ERS #30041) INPUT AND RESET ON

#35001) OUTPUT

ERS is the input to reset the control,

When ERS input is closed, the control stops all of its op-

erations, closing reset On output RSTS for one second. The output signals are opened except
for the following.

Table 20.5

Output Signals

Output at ERS Input Close

AUT, MAN

ZPX – ZP5

3ZPX–3ZP5

4ZPX–3ZP5

5ZPX – 3ZP5

Previous conditions kept.

contact

closed for one

RST

I

second while ERS input contact is

opened.

Contact kept open unless alarm
causing factor is cleared.

Previous conditions kept.

Previous conditions kept.

Note: When

ERS

input is closed, the control is put in the label state.

However, memory is rewound, while the tape is not.

NOTE

The term “label skip” means that the entire information is to be disregarded until the first

of-block code is read after power ON or reset (no parameters disable this label skip feature).

20.2.10 INTERLOCK

# 30042) INPUT

This input stops the spindle travel in the automatic operation mode. As long as “STLK” input is
closed, spindle travel will not start by closing “ST” input.

Even when the STLK input is closed during startup, the control remains in the preceding

state. The STLK input takes effect after the system is brought to a stop by the SBK, feedhold,
or other signal.

20.2.11 ALARM (ALMS # 35000) OUTPUT AND EXTERNAL

#30057) INPUTS

Alarm (ALMS) Output

These outputs inform that the control is in the alarm state.

ERROR DETECT

# 30056,

ALMS: This output is closed on detection of alarm. (However, the alarm for the fault of the logic
circuitry in the control is not included.)

These outputs are opened again when the cause of the detected alarm has been removed

and RESET operation is performed.

136