18.3.2. POWER SUPPLY FOR

SIGNALS

(1)

Internal Power Supply

Internal power supply

for

signals should be provided by the machine tool maker. If

internal power supply is used, calculate the load current according to

points and confirm

that the current is within the allowable current value since there is a current capacity limit

according to

ON points.

The allowable current capacity of the internal power supply is 1. 5A.

Unit consumed current (When internal power supply is used): O. 1A

Panel

consumed current (When internal power is used)

Remote

Input current (l-point): 5.

(at ON)

Output current (1 -point):

max (differs from load,

module

consumed current

Input current (1 -point): 10.

(at ON)

Output current (1 -point):

max (differs from load.

(Example of Calculation)

When JANCD-FC903 All

output are ON with LED load (2.

5.1 mAX64=326.

comsumed current)

24V/2. 7kX32=28.

output comsumed current)

1500mA–326mA–284 mA–100mA=790mA (possible supply current)

If the internal power supply is connected to JANCD-FC800 under these conditions, overcurrent

alarm of the internal power supply (C

or

occurs to the input ON of 77 points or

above.

O. 2mA=77 points

(2) Specifications of External Power Supply