Yaskawa i80M Connecting Manual User Manual

Page 248

Advertising
background image

NOTE

The SNZ input does not affect the positioning commands.
(All positioning commands except the error detect OFF positioning com-

mand

add the “error detect ON” condition to the termination con-

dition set.

21.3.1.12 THREADING INPUT (CDZ #30045)
This input determines whether or not to perform threading during the G92 (threading cycle) or
G76 (complex threading cycle).
When the CDZ input is closed, threading is performed.

When the CDZ input is open, threading does not take place.

The control reads the CDZ input at the beginning of threading cycle to determine whether or

not to perform threading.

When the CDZ input is to be opened or closed with the M command or the like, you should

decide on the CDZ input status at the beginning of threading cycle, considering the delay
caused by input processing.

21.3.1.13 EXTERNAL POWER ON INPUT

#30050)

(1) If this input closes when the NC power is turned ON (the NCMX is ON) by performing the

power ON procedure, the servo power turns ON.

This input is equivalent to turning ON the servo power with the power supply incorporated

This input is effective when parameter pm5012 DO= 1.

When this parameter is selected, the power supply incorporated PB does not accomplish ser-
vo power turn-ON.

NCMX OUTPUT

and above

-

SVMX OUTPUT

Fig. 21.3 External Power On

Input Time Chart