Location

Use the motor under the following conditions.

Indoors

Free from corrosive and/or explosive gases or liquids

Ambient temperature: O to

Clean and dry

Accessible for inspection and cleaning

If the AC servomotor is subject to excessive water or oil droplets, protect motor with a cover.

The motor can withstand a small amount of splashed water or oil.

(3) Environmental Conditions

Ambient Temperature: O to

Storage Temperature: –20 to

Humidity: 20% to 80% RH (non-condensing)

(4)

Load Coupling

True alignment of motor and driven machine is essential to prevent vibration, reduced bearing

and coupling life, or shaft and bearing failures.

Use flexible coupling with direct drive.

The alignment should be made in accordance

with Fig. A8. 2

Fig.

2 Alignment of Coupling

the gap between the straightedge and coupling halves at four equidis-

tant points of the coupling. The each reading should not exceed O.

the shafts.

the gap between the coupling faces at four equidistant points around

the coupling rim with thickness gage

The maximum variation between any two

readings should not exceed O.

(5)

Allowable Bearing Load

Avoid both

and radial loads to the motor shaft. If unavoidable, never exceed the values

in Tables A4.