Yaskawa i80M Connecting Manual User Manual

Page 264

Advertising
background image

NOTE

1. In automatic operation mode part program execution, the feedrate
override for the threading portion is fixed at 100%.

2. A 220 to 540% feedrate override range takes effect only when the

override expansion option is provided.

Feed Override Cancel (OVC #30407)

This is the input for fixing the feedrate override at 10070. When the OVC input contact is
closed, the feed rate in part program execution in the automatic operation modes is locked at
the programmed value, irrespective of the override input conditions.

21.3.2.2

#30405,

#30427)

INPUT

This input is for determining whether data between “/” and

in a part

ecuted or disregarded when the part program contains “/.”

The effective modes are

MEM, TAPE, and

Table 21.13

Neglected Data between

BDT INPUT CLOSED

(End of block)

BDT2 INPUT CLOSED

“/2”

and “EOB”

BDT3

INPUT CLOSED

BDT4 INPUT CLOSED

BDT5 INPUT CLOSED

“/5”

and

BDT6 INPUT CLOSED

“/6”

and “EOB”

BDT7

INPUT CLOSED

BDT8 INPUT CLOSED

“/8”

and

BDT9 INPUT CLOSED

NOTE

Data can be disregarded only when part programs are executed.

When storing part programs into memory, this input has no effect.

The optional block delete input status prevailing when a part prog-

ram block containing “/” is stored into buffer, determines whether data
are to be considered significant or disregarded.

Therefore, when controlling the optional block delete input status using
the auxiliary function and an external circuit, ensure that the input status

is set up before the block containing “/” is stored into buffer.

264

Advertising