Yaskawa i80M Connecting Manual User Manual

Page 247

Advertising
background image

21. 3.1.9 EXTERNAL RESET Inputters #30041 )

A N D R E S E T O N O U T P U T

(

R S T S

# 3 5 0 0 1 )

The ERS input resets each program of the control.
When the ERS input is closed, the control stops the entire operation of the associated program

and closes the RSTS output for second.

The output signals open except as indicated in Table

21.6.

NOTE: While cooperative multi-program control is being exercised, all the cooperating prog-
rams are reset.

Table 21.6 “Closed’’Output Signals

Output Signal Name

AUT, MAN,

* ESPS

Various monitor outputs
(except the program opera-
tion status monitor output)

RSTS

ALMS

TO-T9 Spindle control signal

Output Generated when the ERS

is closed

The previous state is retained.

The output is closed while the ERS input is

or for

1 second after the ERS input is opened.

The output is left closed if no alarm condition remains,

The previous state is retained.

The previous state is retained

NOTE

When the ERS input is closed, the memory is rewound, but the tape is

not.

21.3.1.10 START INTERLOCK INPUT

# 30042)

This input is used to prohibit automatic operation mode startup.

While the STLK input is closed, startup does not take place even if the ST input closes

21.3.1.11 ERROR DETECT ON INPUT (SMZ # 30044)

This input determines whether or not to add the “error detect ON” condition to the automatic
mode cutting feed termination condition set.

Due to the delay elements of the servo system, the position detection operations performed by

the position detector provide delayed follow-up relative to the positions designated by the logic
circuit in the course of machine traveling.

The “error detect ON” state refers to the situation in

which the difference between the designated and detected positions is smaller than the para-

meter

settings,

When the SMZ

is closed, the “error detect ON” condition is added to the automatic mode

cutting feed termination condition set. This condition addition does not take place if the SMZ
input is open.

247