20.2.47 END-OF-PROGRAM (EOP # 30410) INPUT, REWIND (RWD # 3041’

WIND ON

# 35376) OUTPUTS

End-of-Program (EOP #3041 O) and Rewind (RWD #30411) Inputs

With these outputs, the control determines what processing is to be perform

INPUT, AND

at completion of

an M02 or M30 command. The control performs the following processing depending on the
state of EOP and RWD inputs when completion input FIN for an M02 or M30 command is

opened, then closed.

Table 20.17

EOP

RWD

Processing

The control is at standby after rewinding part programs and

1

1

resetting programs.

1

O

is at standby after resetting programs.

O

1

The control is at standby after resetting part programs.

o

0

The control is at standby.

1: Closed,

O:

Open

Note:

1. Program reset provides the same effects as with depressing of RESET key

MDI panel and the reset operation by closing External Reset

input. In the

program reset, however, the NC memory rewind operation is not performed. For de-

tails of the reset operation by closing ERS input, refer to par.

EXTERNAL RESET

INPUT,

2. RST is closed for a second during program resetting.

(2) Rewinding State Output

#35376)

This output is generated to indicate that the control is rewinding a part program.

When a part program is rewound by the RWD input in response to the M02 or M30 command,

the RWDS is closed during rewinding.

20.2.48 OPTIONAL STOP (OPT # 30406) INPUT

This input determines whether or not to execute the MO1 command in the automatic operation

mode (TAPE, MEM,

When the OPT is ON
After the block containing MO1 is executed, the machine stops with the cycle start (ST) re-
maining closed (the cycle start opens when the FIN signal input is returned). The machine
restarts when the ST turns ON.

When the OPT is OFF
The MO1 command is disregarded.
This. input does not work on the currently executed block.

In the automatic operation mode,

it works on the newly read blocks.

164