Yaskawa i80M Connecting Manual User Manual
Page 312

M
.
A
o
B
‘ N
0
0
R
“H
Detector receptacle
A
Channel A output
J
F. G
B
Channel
output
K
c
Channel B output
L
D
Channel
output
M
E
Channel Z output
N
F
Channel
output
P
G
R
Reset
H
V (Power Supply)
s
O V (Battery)
T
+3. 6 V (Battery)
A4. 5.5 Shock Resistance
When mounted horizontally and exposed to vertical shock impulses, the motor can withstand up
to two incidents with shock acceleration of
10G
(Fig. A4. 7).
NOTE
A Precision detector is mounted on the opposite-drive end
of AC servomotor. Care should be taken to protect the
shaft from impacts that could damage the detector.
VERTICAL
HORIZONTAL
Fig.
Shock Resistance
A4. 5.6 Vibration Resistance
When mounted horizontally, the motor can withstand vibration (vertical, lateral, axial) of 2.5 G
(Fig. A4. 8).
Fig.
8 Vibration Resistance
A4. 5.7 Vibration Class
Vibration of the motor running at rated speed is
or below (Fig. A4. 9),
. .
POSITION FOR
CHECKING VIBRATION
Fig. A4. 9 Vibration Checking
312