6. Tie Angles, Ladders and Safety Cages

Chapter 6: Tie Angles, Ladders and Safety Cages

Attach Tie Angle to Boot Trunking

1. When installing the tie angles, be sure sides with the notches face out away from the trunk and the

side with the straight edge is installed against the trunking angles. Only one tie angle for the ladder
side and one tie angle for the non-ladder side is used.

a. For 42" Boot Tie Angle: Install the tie angle (GECT4204X or BECT4204X) to both sides of the

trunking attached at the boot using 1/2" x 1" HHCS bolts (S-7935) and 1/2" flange nuts (S-8506).

(See Figure 6A.)

Figure 6A 42" Boot Tie Angle

b. For 48" Boot Tie Angle: Install the tie angle (GECT4804X or BECT4804X) to both sides of the

trunking attached at the boot using 1/2" x 1" HHCS bolts (S-7935) and 1/2" flange nuts (S-8506).

(See Figure 6B.)

Figure 6B 48" Boot Tie Angle