Rest platform, Chapter 7 rest platform, Install rest platform tie angles to trunking – Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-1842 User Manual
Page 40
Advertising

40
PNEG-1842 42"-48" Bucket Elevator Platform and Ladder “X” Series
7. Rest Platform
Chapter 7: Rest Platform
Install Rest Platform Tie Angles to Trunking
1. For 42" Rest Platform Tie Angles:
NOTE: The end of the tie angle with the greater distance to the first notch must be installed toward
the down-leg trunking.
Install the rest platform tie angles (RP42CHNLX) to the lower trunking on both the ladder and
non-ladder sides using 1/2" x 1" HHCS bolts (S-7935) and 1/2" flange nuts (S-8506).
Figure 7A 42" Rest Platform Tie Angles - Ladder Side
Figure 7B 42" Rest Platform Tie Angles - Non-Ladder Side