Do not make any connection in the

pump control box unless the power

supply has been switched off for at least

2 minutes.

For models with "plug

connector" (25-40,

25-60, 32-40, 32-60).

See

Figure 16

.

1. Open the connector

cover and insert the

cable inside the ca-

ble gland.

2. Pull down the con-

tact retention

spring.

3. Connect the cable

according to the

wiring diagram.

4. Align the two parts

of the connector

5. Push the two parts

one inside the other.

6. Close the connector

and tighten carefully

to the cable gland.

For models with a stand-

ard terminal block con-

nection. See

Figure 15

.

1. Open the terminal

box cover removing

the screws (5).

2. Use the M20 cable

gland for the power

cable.

3. Connect the cable

according to the

wiring diagram. See

Figure 17

and

Fig-

ure 19

.

a. Connect the ground

(earth) lead. Make

sure that the ground

(earth) lead is longer

than the phase

leads.

b. Connect the phase

leads.

4. Close the terminal

box cover and tight-

en the screws to 1

Nm.

For cable requirements, see

Connection assign-

ment

.

4.6.2 I/O connections

1. Open the terminal box cover removing the

screws (5). See

Figure 14

and

Figure 15

2. Connect the appropriate cable according to

the terminal block diagram. See

Figure 18

,

Figure 19

and the requirements of section

Connection assignment

.

3. Close the terminal box cover and tighten the

screws to 1 Nm.

4.6.3 Connection assignment

NOTICE:

• For all the connections use heat resistant cable

up to +85°C (+185°F). The cables never have to

touch the motor housing or the pump or the

pipeline.

• Wires connected to supply terminals and fault

signal relay (NO,C) must be separated from oth-

ers by reinforced insulation.

Only for

25-40,

25-60,

32-40,

32-60 Mod-

els

PLUG Con-

nector

M12 (1) Ca-

ble Φ 2÷5

mm

M12 (2) Ca-

ble Φ 2÷5

mm

Power sup-

ply

3 x

0.75÷1.5m

m

2

(2P+T)

Fault signal

2 x

0.75÷1.5m

m

2

• Analog

0-10V

• External

pres-

sure

sensor

• External

temper-

ature

sensor

• External

Start/

Stop

If NO fault

signal on

this cable

gland. Mul-

tiwire con-

trol cable,

number of

wires ac-

cording to

number of

control cir-

cuits.

Shielded if

necessary

Multiwire

control ca-

ble, num-

ber of wires

according

to number

of control

circuits.

Shielded if

necessary

Communi-

cation bus

Bus cable

M20 Cable

Φ

5÷13

mm

M16 (1)

M16 (2)

Power sup-

ply

3 x

0.75÷2.5

mm

2

(2P

+T)

- Power

supply
- Fault sig-

nal

5 x

0.75÷1.5

mm

2

(4P

+T)

Fault signal

2 x

0.75÷1.5m

m

2

• Analog

0-10V

• External

pres-

sure

sensor

• External

temper-

ature

sensor

• External

Start/

Stop

If NO fault

signal on

this cable

gland. Mul-

tiwire con-

trol cable,

number of

wires ac-

cording to

number of

control cir-

cuits.

Shielded if

necessary

Multiwire

control ca-

ble, num-

ber of wires

according

to number

of control

circuits.

Shielded if

necessary

en - Translation of the original instructions

21

Advertising