Add Frequency – The inverter can add or subtract on offset value to the output
frequency setting which is specified by A001 (will work with any of the five possible
sources). The ADD Frequency is a value you can store in parameter A145. the ADD
Frequency is summed with or subtracted from the output frequency setting only when
the [ADD] terminal is ON. Function A146 selects whether to add or subtract. By
configuring an intelligent input as the [ADD] terminal, your application can selectively
apply the fixed value in A145 to offset (positively or negatively) the inverter output
frequency in real time.

“A” Function

Defaults

Func.

Code

Name /

SRW Display

Description

Run

Mode

Edit

-FE

(EU)

-FU

(USA)

Units

ADD frequency

A145

ST-PNT

0000.0Hz

An offset value that is applied to
the output frequency when the
[ADD] terminal is ON.
Range is 0.0 to 400.0 Hz

9

0.0

0.0

Hz

ADD direction select

A146

ADD DIR

PLUS

Two options:
00

}Plus (adds A145 value to the

output frequency setting)

01

}Minus (subtracts A145 value

from the output frequency
setting)

U

00

00



Keypad potentiometer

Control terminal

Function F001 setting

ModBus network input

Calculate function output

Ȉ

+

A001

Frequency source setting

Output frequency setting

A145 ADD frequency

A146

ADD direction select

+/-

Intelligent input

[ADD]

3

30

Config

uri

ng Driv

e

Parameters

3

−30

&RQ¿JXULQJ'ULYH

Parameters