The X200 inverter has the capability to store and output up to 16 preset frequencies to
the motor (A020 to A035). As in traditional motion terminology, we call this

multi-speed

profile

capability. These preset frequencies are selected by means of digital inputs to the

inverter. The inverter applies the current acceleration or deceleration setting to change
from the current output frequency to the new one. The first multi-speed setting is
duplicated for the second motor settings (the remaining 15 multi-speeds apply only to
the first motor).

The jog speed setting is used whenever the Jog command is active. The jog speed setting
range is arbitrarily limited to 10 Hz, to provide safety during manual operation. The
acceleration to the jog frequency is instantaneous, but you can choose from three modes
for the best method for stopping the jog operation.

“A” Function

Defaults

Func.

Code

Name /

SRW Display

Description

Run

Mode

Edit

-FE

(EU)

-FU

(USA)

Units

Multi-speed frequency setting

A020

SPD 00s

0000.0Hz

Defines the first speed of a multi-
speed profile, range is 0.0 / start
frequency to 400Hz
A020 = Speed 0 (1st motor)

9

0.0

0.0

Hz

Multi-speed frequency
setting, 2nd motor

A220

2SPD00s

0000.0Hz

Defines the first speed of a multi-
speed profile or a 2nd motor,
range is 0.0 / start frequency to
400Hz
A220 = Speed 0 (2nd motor)

9

0.0

0.0

Hz

Multi-speed frequency
settings
(for both motors)

Defines 15 more speeds,
range is 0.0 / start frequency to
400 Hz.
A021=Speed 1 ~ A035=Speed15

See

next

row

See

next

row

A021

to

A035

SPD 01s

000.0Hz

SPD 02s

000.0Hz

SPD 03s

000.0Hz

SPD 04s

000.0Hz

SPD 05s

000.0Hz

SPD 06s

000.0Hz

SPD 07s

000.0Hz

SPD 08s

000.0Hz

SPD 09s

000.0Hz

SPD 10s

000.0Hz

SPD 11s

000.0Hz

SPD 12s

000.0Hz

SPD 13s

000.0Hz

SPD 14s

000.0Hz

SPD 15s

000.0Hz

A021
A022
A023
A024
A025
A026
A027
A028
A029
A030
A031
A032
A033
A034
A035

9

0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0

0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0

Hz

Jog frequency setting

A038

Jog-F

001.00Hz

Defines limited speed for jog,
range is 0.00 / start frequency to
9.99 Hz

9

1.00

1.00

Hz

Jog stop mode

A039

Jog-Mode

FRS

Define how end of jog stops the
motor; three options:
00

}Free-run stop

01

}Controlled deceleration

02

}DC braking to stop

U

00

00



3

15

Config

uri
ng Driv

e

Parameters

3

−15

&RQ¿JXULQJ'ULYH

Parameters

Advertising