Determining Wire and Fuse Sizes

The maximum motor currents in your application determines the recommended wore
size. The following table gives the wire size in AWG. The “Power Lines” column applies
to the inverter input power, output wires to the motor, the earth ground connection, and
any other components shown in the “Basic System Description” on

page 2-7

. The “Signal

Lines” column applies to any wire connecting to the two green connectors just inside the
front cover panel.

Motor Output

Wiring

Applicable

equipment

kW

HP

Inverter Model

Power Lines

Signal Lines

Fuse (UL-rated,

class J, 600V)

0.2

1/4

X200-002SFEF/NFU

10A

0.4

1/2

X200-004SFEF/NFU

10A

0.55

3/4

X200-005SFEF

10A

0.75

1

X200-007SFEF/NFU

AWG14 / 2.1mm

2

15A

1.1

1 1/2

X200-011SFEF

15A

1.5

2

X200-015SFEF/NFU

20A

2.2

3

X200-022SFEF/NFU

AWG10 / 5.3mm

2

30A

3.7

5

X200-037LFU

AWG12 / 3.3mm

2

30A

5.5

7 1/2

X200-055LFU

AWG10 / 5.3mm

2

40A

7.5

10

X200-075LFU

AWG8 / 8.4mm

2

50A

0.4

1/2

X200-004HFEF/HFU

3A

0.75

1

X200-007HFEF/HFU

6A

1.5

2

X200-015HFEF/HFU

AWG16 / 1.3mm

2

2.2

3

X200-022HFEF/HFU

10A

3.0

4

X200-030HFEF

4.0

5

X200-040HFEF/HFU

AWG14 / 2.1mm

2

(60

qC only)

15A

5.5

7 1/2

X200-055HFEF/HFU

20A

7.5

10

X200-075HFEF/HFU

AWG12 / 3.3mm

2

(60

qC only)

18 to 28 AWG /
0.14 to 0.75 mm

2

shielded wire
(see Note 4)

25A

Note 1: Field wiring must be made by a UL-Listed and CSA-certified closed-loop

terminal connector sized for the wire gauge involved. Connector must be fixed
by using the crimping tool specified by the connector manufacturer.

Note 2: Be sure to consider the capacity of the circuit breaker to be used.
Note 3: Be sure to use a larger wire gauge if power line length exceeds 66ft. (20m).
Note 4: Use 18 AWG / 0.75mm

2

wire for the alarm signal wire ([AL0], [AL1], [AL2]

terminals).