IGBT Test Method

The following procedure will check the inverter transistors (IGBTs) and diodes:

1. Disconnect input power to terminals [R, S, and T] and motor terminals [U, V, and W].

2. Disconnect any wires from terminals [+] and [–] for regenerative braking.

3. Use a Digital Volt Meter (DVM) and set it for 1

Ÿ resistance range. You can check the

status of the charging state of terminals [R, S, T, U, V, W, +, and –] of the inverter
and the probe of the DVM by measuring the charging state.

Table Legend

Almost infinite resistance:

# ’ Ÿ Almost zero resistance: # 0 Ÿ

DVM

DVM

DVM

Part

+

Measured

Value

Part

+

Measured

Value

Part

+

Measured

Value

[R]

[+1]

# ’ Ÿ

[S] [–]

# 0 Ÿ

[W] [+]

# ’ Ÿ

D1

[+1]

[R]

# 0 Ÿ

D5

[–] [S]

# ’ Ÿ

TR3

[+] [W]

# 0 Ÿ

[S]

[+1]

# ’ Ÿ

[T] [–]

# 0 Ÿ

[U] [–]

# 0 Ÿ

D2

[+1]

[S]

# 0 Ÿ

D6

[–] [T]

# ’ Ÿ

TR4

[–] [U]

# ’ Ÿ

[T]

[+1]

# ’ Ÿ

[U] [+]

# ’ Ÿ

[V] [–]

# 0 Ÿ

D3

[+1]

[T]

# 0 Ÿ

TR1

[+] [U]

# 0 Ÿ

TR5

[–] [V]

# ’ Ÿ

[R]

[–]

# 0 Ÿ

[V] [+]

# ’ Ÿ

[W] [–]

# 0 Ÿ

D4

[–]

[R]

# ’ Ÿ

TR2

[+] [V]

# 0 Ÿ

TR6

[–] [W]

# ’ Ÿ

NOTE: The resistance values for the diodes or the transistors will not be exactly the
same, but they will be close. If you find a significance difference, a problem may exist.

NOTE: Before measuring the voltage between [+] and [–] with the DC current range,
confirm that the smoothing capacitor is discharged fully, then execute the tests.