“A” Group: Standard Functions

The inverter provides flexibility in how you control Run/Stop operation and set the
output frequency (motor speed). It has other control sources that can override the A001
/ A002 settings. Parameter A001 sets the source selection for the inverter’s output
frequency. Parameter A002 selects the Run command source (for FW or RV Run
commands). The default settings use the input terminals for –FE (European) models,
and the keypad for –FU (USA) models.

“A” Function

Defaults

Func.

Code

Name /

SRW Display

Description

Run

Mode

Edit

-FE

(EU)

-FU

(USA)

Units

Frequency source setting

A001

F-COM

VR

U

01

00



Frequency source setting,
2nd motor

A201

2F-COM

VR

Five options; select codes:
00

}Keypad potentiometer

01

}Control terminal

02

}Function F001 setting

03

}ModBus network input

10

}Calculate function output

U

01

00



Run command source setting

A002

OPE-Mode

REM

U

01

02



Run command source setting,
2nd motor

A202

OPE-Mode

REM

Three options; select codes:
01

}Control terminal

02

}Run key on keypad,

or digital operator

03

} ModBus network input

U

01

02



Frequency Source Setting – For parameter A001, the following table provides a further
description of each option, and a reference to other page(s) for more information.

Code

Frequency Source

Refer to page(s)…

00

Keypad potentiometer – The range of rotation of the knob
matches the range defined by B082 (Start frequency
adjustment) to A004 (Maximum frequency setting)

2-24

01

Control terminal – The active analog input signal on analog
terminals [O] or [OI] sets the output frequency

4-53, 3-13, 3-28,

3-49

02

Function F001 setting – The value in F001 is a constant,
used for the output frequency

3-9

03

ModBus network input – The network has a dedicated
register for inverter output frequency

B-19

10

Calculate function output – The Calculated function has
user-selectable analog input sources (A and B). The output
can be the sum, difference, or product (+, -, x) of the two
outputs.

3-29

3

10

Config

uri

ng Driv

e

Parameters

3

−10

&RQ¿JXULQJ'ULYH

Parameters

Advertising