List of Holding Registers

Network Data

Func.

Code

Name

R/W

Description

Reg.

Res.

R

Trip monitor 1: factor code

0012h



R

Frequency

0014h

0.1 Hz

R

Current

0016h

0.1A

R

Voltage

0017h

1.V

R

Run time (high)

0018h

R

Run time (low)

0019h

1. h

R

ON time (high)

001Ah

D081

Trip monitor 1

R

ON time (low)

001Bh

1. h

R

Trip monitor 2: factor code

001Ch



R

Frequency

001Eh

0.1 Hz

R

Current

0020h

0.1A

R

Voltage

0021h

1.V

R

Run time (high)

0022h

R

Run time (low)

0023h

1. h

R

ON time (high)

0024h

D082

Trip monitor 2

R

ON time (low)

0025h

1. h

R

Trip monitor 3: factor code

0026h



R

Frequency

0028h

0.1 Hz

R

Current

002Ah

0.1A

R

Voltage

002Bh

1.V

R

Run time (high)

002Ch

R

Run time (low)

002Dh

1. h

R

ON time (high)

002Eh

D083

Trip monitor 2

R

ON time (low)

002Fh

1. h