B−33, B 33 – XLT Hitachi X200 User Manual

Page 276

Advertising
background image

List of Holding Registers

Network Data

Func.

Code

Name

R/W

Description

Reg.

Range

Res.

B052

OV-LAD Stop level of
non stop operation
setting

R/W Setting the OV-LAD stop level of

non stop operation. Range is 0.0
to 1000.0

10CBh

0 to 10000

0.1 V

B053

Deceleration time of
non stop operation
setting

R/W Range is 0.1 to 3000

10CCh

1 to 30000

0.1 sec

B054

Frequency width of
quick deceleration
setting

R/W Setting of the first quick

deceleration width. Range is 0.0
to 10.0

10CEh

0 to 100

0.1 Hz

B055

DC bus AVR P-gain

R/W Proportional gain adjustment for

DC bus AVR function. Range is:
0.2 to 5.0

1173h

2 to 50

0.1

B056

DC bus AVR I-time

R/W Integration time adjustment for

DC bus AVR function. Range is:
0.0 to 150.0

1174h

0 to 1500

0.1s

B080

[AM]analog signal gain R/W Adjust of analog output at

terminal [AM],
range is 0 to 255

10CFh

0 to 255



B082

Start frequency
adjustment

R/W Sets the starting frequency for

the inverter output, range is 0.5
to 9.9 Hz

10D1h

5 to 99

0.1 Hz

B083

Carrier frequency
setting

R/W Sets the PWM carrier (internal

switching frequency), range is
2.0 to 12.0 kHz

10D2h

20 to 120

0.1 Hz

B084

Initialization mode
(parameters or trip
history)

R/W Select the type of initialization to

occur, three option codes:
00

}Trip history clear

01

}Parameter initialization

02

} Trip history clear and

parameter initialization

10D3h

0, 1, 2



B085

Country for
initialization

R/W Select default parameter values

for country on initialization,
three option codes:
00

}Japan

01

}Europe

02

}US

10D4h





B

33

B

−33

Appendix B

Advertising