XLT Hitachi X200 User Manual

Page 77

Advertising
background image

If the Potentiometer Enable LED is OFF, follow these steps below.

Action

Display

Func./Parameter

(Starting point)

A- - -

“A” Group selected

Press the key.

A001

Speed command source setting

Press the key again.

01

00 = Keypad potentiometer
01 = Control terminals
02 = Function F001 setting
03 = ModBus network
04 = Calculate function output

Press the key.

00

00 = Potentiometer (selected)

Press the key.

A001

Store parameter, returns to “A”
Group list

Select the Keypad for RUN Command – To RUN
command causes the inverter to accelerate the motor
to the selected speed. The Run command can arrive
from various sources, including the control terminals,
the Run key on the keypad or the network. In the
figure to the right, notice the Run Key Enable LED,
just above the Run key. If the LED is ON, the Run
key is already selected as the source, and you may
skip this step. Note that the default setting depends
on the country.

If the Potentiometer Enable LED is OFF, follow these steps below (the table resumes
action from the end of the previous table).

Action

Display

Func./Parameter

(Starting point)

A001

Speed command source setting

Press the key once.

A002

Run command source setting

Press the key.

01

01 = Control terminals
02 = Run key on keypad
03 = ModBus network

Press the key.

02

02 = Run key on keypad (selected)

Press the key.

A002

Store parameter, returns to “A”
Group list

NOTE: After completing the steps above, the Run Key Enable LED will be ON. This
does not mean the motor is trying to run; it means that the RUN key is now enabled.
DO NOT press the RUN key at this time – complete the parameter setup first.

FUNC

2

FUNC

STR

FUNC

STR

1

1

2

30

Inverter Mounting

and i

n

st

all

ation

Run Key Enable LED

PRG

RUN

Hz

RUN

A

2

POWER

ALARM

STOP

RESET

1

FUNC

STR

2

−30

Inverter Mountingand

installation

Advertising