Use one BRD-E3 braking unit for the braking torque listed in the following table.

Note the column meanings in the tables:

x

Column “A” = Average braking torque from 60Hz to 3Hz.

x

Column “B” = Average braking torque from 120Hz to 3Hz.

X200 Inverter 200V Models

Braking Torque with BRD-E3 Braking Unit

External resistor added

Using built-in

resistor only

HRB1

HRB2

HRB3

Model Number

HP

Braking

torque

without

braking unit

A

B

A

B

A

B

A

B

002SFEF/NFU

1/4

50%

150%

120%

004SFEF/NFU

1/2

50%

150%

120%

005SFEF

3/4

50%

150%

120%

007SFEF/NFU

1

50%

100%

80%

150%

120%

011SFEF

1.5

50%

60%

60%

100%

80%

015SFEF/NFU

2

50%

50%

50%

100%

80%

022SFEF/NFU

3

20%

50%

50%

100%

80%

037LFU

5

20%

40%

40%

60%

60%

100%

100%

150%

120%

055LFU

7.5

20%

30%

30%

50%

50%

70%

70%

100%

80%

075LFU

10

20%

20%

20%

40%

40%

50%

50%

80%

80%

Connect a second braking unit in parallel for additional braking torque listed in the
following table.

X200 Inverter 200V Models

Braking Torque with BRD-E3 Braking Unit

External resistor added

Using built-in

resistor only

HRB1

HRB2

HRB3

Model Number

HP

Braking

torque

without

braking unit

A

B

A

B

A

B

A

B

002SFEF/NFU

1/4

50%

150%

120%

004SFEF/NFU

1/2

50%

150%

120%

005SFEF

3/4

50%

150%

120%

007SFEF/NFU

1

50%

150%

120%

011SFEF

1.5

50%

100%

80%

015SFEF/NFU

2

50%

100%

80%

022SFEF/NFU

3

20~40%

70%

70%

150%

120%

037LFU

5

20~40%

50%

50%

110%

90%

055LFU

7.5

20%

30%

30%

80%

80%

100%

100%

150%

150%

075LFU

10

20%

30%

30%

60%

60%

80%

80%

100%

100%

5

6

5

−6

Inverter System

Accessories