List of Holding Registers

Network Data

Func.

Code

Name

R/W

Description

Reg.

Range

Res.

B133

DC bus AVR
selection

R/W Two option codes:

00

}Disabled

01

}Enabled

1176h

0, 1



B134

Threshold voltage of
DC bus AVR setting

R/W Setting of threshold voltage of DC bus

voltage to start DC bus AVR function.
Range is:
200V class

}330 to 395

400V class

}660 to 790

1177h 330 to 395,

660 to 790

1 V

B140

Over-current trip
suppression

R/W Two option codes:

00

}Disable

01

}Enable

10F7h

0, 1



B150

Carrier mode

R/W Automatically reduces the carrier

frequency as the ambient temperature
increases.
00

}Disable

01

}Enable

10F8h

0, 1



B151

Selection of RDY
function

R/W Select Ready function.

00

}Disable

01

}Enable

10F9h

0, 1



Note 1:

Assume that the inverter current rating is 10000 (for B013/B213).

B

35

Appe

ndix B

B

−35

Appendix B