Miscellaneous Functions

The following table contains miscellaneous functions not in other function groups.

“C” Function

Defaults

Func.

Code

Name /

SRW Display

Description

Run

Mode

Edit

-FE

(EU)

-FU

(USA)

Units

Debug mode enable *

C091

DBG Slct

OFF

Displays debug parameters.
Two option codes:
00

}Disable

01

}Enable <Do not set>

(for factory use)

9

00

00



Up/Down memory mode
selection

C101

UP/DWN

NO-STR

Controls speed setpoint for the
inverter after power sycle.
Two option codes:
00

}Clear last frequency (return to

default frequency F001)

01

}Keep last frequency adjusted

by UP/DWN

U

00

00



Reset selection

C102

RS Slct

ON

Determines response to Reset
input [RS].
Three option codes:
00

}Cancel trip state at input

signal ON transition, stops
inverter if in Run Mode

01

}Cancel trip state at signal

OFF transition, stops inverter
if in Run Mode

02

}Cancel trip state at input ON

transition, no effect if in Run
Mode

U

00

00



CAUTION: Do not change Debug mode for safety reasons. Otherwise unexpected
performances may occur.

3

62

Config

uri
ng Driv

e

Parameters

3

−62

&RQ¿JXULQJ'ULYH

Parameters