A 7 – XLT Hitachi X200 User Manual

Page 242

Advertising
background image

Setpoint (SP)

The

setpoint

is the desired value of a process variable of interest. See

also

Process Variable (PV)

and

PID Loop

.

Single-phase power

An AC power source consisting of Hot and Neutral wires. An Earth
Ground connection usually accompanies them. In theory, the voltage
potential on Neutral stays at or near Earth Ground, while Hot varies
sinusoidally above and below Neutral. This power source is named
Single Phase to differentiate it from three-phase power sources. Some
Hitachi inverters can accept single phase input power, but they all
output three-phase power to the motor. See also T

hree-phase

.

Slip

The difference between the theoretical speed of a motor at no load
(determined by its inverter output waveforms) and the actual speed.
Some slip is essential in order to develop torque to the load, but too
much will cause excessive heat in the motor windings and/or cause
the motor to stall.

Squirrel Cage

A “nick-name” for the appearance of the rotor frame assembly for an
AC induction motor.

Stator

The windings in a motor that are stationary and coupled to the power
input of the motor. See also

Rotor

.

Tachometer

1.

A signal generator usually attached to the motor shaft for the
purpose of providing feedback to the speed controlling device of
the motor.

2.

A speed-monitoring test meter that may optically sense shaft
rotation speed and display it on a readout.

Thermal Switch

An electromechanical safety device that opens to stop current flow
when the temperature at the device reaches a specific temperature
threshold. Thermal switches are sometimes installed in the motor in
order to protect the windings from heat damage. The inverter can use
thermal switch signals to trip (shut down) if the motor overheats. See
also

Trip

.

Thermistor

A type of temperature sensor that changes its resistance according to
its temperature. The sensing range of thermistors and their
ruggedness make them ideal for motor overheating detection. Hitachi
inverters have built-in thermistor input circuits, which can detect an
overheated motor and shut off (trip) the inverter output.

Three-phase power

An AC power source with three Hot connections that have phase
offsets of 120 degrees is a 3-phase power source. Usually, Neutral and
Earth Ground wires accompany the three Hot connections. Loads
may be configured in a delta or Y configuration. A Y-connected load
such as an AC induction motor will be a balanced load; the currents
in all the Hot connections are the same. Therefore, the Neutral
connection is theoretically zero. This is why inverters that generate
3-phase power for motors do not generally have a Neutral connection
to the motor. However, the Earth Ground connection is important for
safety reasons, and is provided.