B−32, B 32 – XLT Hitachi X200 User Manual

Page 275

Advertising
background image

List of Holding Registers

Network Data

Func.

Code

Name

R/W

Description

Reg.

Range

Res.

B021

Overload restriction
operation mode

R/W

10B5h

B221

Overload restriction
operation mode, 2nd
motor

Select the operation mode during
overload conditions, three
options, option codes:
00

}Disables

01

}Enabled for acceleration and

constant speed

02

}Enabled for constant speed

only

1529h

0, 1, 2



B022

Overload restriction
level setting

R/W

10B6h

B222

Overload restriction
level setting, 2nd
motor

R/W

Sets the level for overload
restriction, between 20% and
150% of the rated current of the
inverter, setting resolution is 1%
of rated current

152Ah

2000 to

15000

0.01%

B023

Deceleration rate at
overload restriction

R/W

10B7h

B223

Deceleration rate at
overload restriction,
2nd motor

R/W

Sets the deceleration rate when
inverter detects overload, range
is 0.1 to 30.0, resolution 0.1

152Bh

1 to 300

0.1 sec

B028

Source of overload
restriction selection

R/W Two option codes:

00

}set value of B022

01

}[O] input

10BBh

B228

Source of overload
restriction selection,
2nd motor

R/W Two option codes:

00

}set value of B222

01

}[O] input

152Ch

0, 1



B029

Deceleration rate of
frequency pull-in
restart setting

R/W Sets the deceleration rate when

frequency pull-in restart, range
is 0.1 to 3000.0, resolution 0.1

1171h

1 to 30000

0.1 sec

B030

Current level of
frequency pull-in
restart setting

R/W Sets the current level of

frequency pull-in restart, range
is 0.2*inverter rated current to
2.0*inverter rated current,
resolution 0.1

1172h

200 to

20000

0.01%

B031

Software lock mode
selection

R/W Prevents parameter changes, in

four options, option codes:
00

}all parameters except B031

are locked when [SFT]
terminal is ON

01

}all parameters except B031

and output frequency F001
are locked when [SFT]
terminal is ON

02

}all parameters except B031

are locked

03

}all parameters except B031

and output frequency F001
are locked

10

}High level access including

B031

10BCh

0, 1, 2, 3



B050

Selection of the non
stop operation

R/W Two option codes:

00

}Disabled

01

}Enabled

10C9h

0, 1



B051

Non stop operation
start voltage setting

R/W Setting of DC bus voltage to start

non stop operation. Range is 0.0
to 1000.0

10CAh

0 to 10000

0.1 V

B

32

Appe

ndix B

B

−32

Appendix B