“B” Function

Defaults

Func.

Code

Name /

SRW Display

Description

Run

Mode

Edit

-FE

(EU)

-FU

(USA)

Units

[AM] analog signal gain

B080

AM-Adj

00100%

Adjust of analog output at
terminal [AM],
range is 0 to 255

9

100.

100.



Start frequency adjustment

B082

fmin

0000.5Hz

Sets the starting frequency for
the inverter output, range is 0.5
to 9.9 Hz

U

0.5

0.5

Hz

Carrier frequency setting

B083

Carrier

0003.0

Sets the PWM carrier (internal
switching frequency), range is 2.0
to 12.0 kHz

U

3.0

3.0

kHz

Initialization mode
(parameters or trip history)

B084

INIT Mode

TRP

Select the type of initialization to
occur, three option codes:
00

}Trip history clear

01

}Parameter initialization

02

} Trip history clear and

parameter initialization

U

00

00



Country for initialization

B085

INIT Slct

EU

Select default parameter values
for country on initialization,
three option codes:
00

}Japan

01

}Europe

02

}US

U

01

02



Frequency scaling conversion
factor

B086

Cnv Gain

0001.0

Specify a constant to scale the
displayed frequency for D007
monitor, range is 0.1 to 99.9

9

1.0

1.0



STOP key enable

B087

STP Key

ON

Select whether the STOP key on
the keypad is enabled,
two option codes:
00

}Enabled

01

}Disabled

U

00

00



3