Displaying running configuration – Brocade Multi-Service IronWare Switching Configuration Guide (Supporting R05.6.00) User Manual

Page 244

Advertising
background image

214

Multi-Service IronWare Switching Configuration Guide

53-1003036-02

Displaying multi-port static MAC address information

7

Error: port 4/11 is part of multiport-mac and cannot be added as secondary

port of a trunk

•

When a LAG primary port is part of a multi-port static MAC address, the LAG cannot be
undeployed or deleted. Also, when a non-LAG port is part of a multi-port static MAC address,
you cannot deploy a LAG with that port. These configurations will be rejected. The following are
the sample error messages for each of these cases:

-

Veto check for deploying LAG.

Brocade(config-lag-LAG1)#deploy

Error: LAG LAG1 primary port 4/11 is configured as part of a multi-port mac

entry, cannot deploy the LAG

-

Veto check for undeploying LAG.

Brocade(config-lag-LAG2)#no deploy

Error: The primary port 4/15 is configured as part of a multi-port mac

entry, cannot undeploy the LAG

-

Veto check for deleting LAG.

Brocade(config)#no lag LAG2

Error: The primary port 4/15 is configured as part of a multi-port mac

address, cannot remove the LAG

•

A port belonging to a multi-port static MAC address is not allowed to be removed from a VLAN
unless it is removed from all the multi-port static MAC addresses.

Brocade(config-vlan-100)#no tag e 2/19

Error - port 2/19 is configured as part of a multi-port mac address, cannot

remove port from vlan

•

Module configuration deletion (no module) will be rejected if any of the ports in that module
are configured as part of any multi-port static MAC addresses.

Brocade(config)#no mod 4 ni-mlx-20-port-1g-100fx

Error - module 4 has ports that are member of the multi-port mac addresses,

Cannot remove the module

Displaying multi-port static MAC address information

You can display the following information about multi-port static MAC addresses on the device:

•

Running configuration

•

Changes in the MAC table

•

M-port debug information

•

LP information

Displaying running configuration

To display the running configuration information of multi-port static MAC addresses, enter the
following command.

Brocade# show run

vlan 10

tagged ethe 1/1 to 1/20 ethe 2/1 to 2/48

static-mac-address 0100.5e42.7f40 multi-ports ethe 1/1 to 1/3