MMRP networks

21

Brocade_AS1(config-if-e10000-1/1)#port-type backbone-network

Brocade_AS1(config-if-e10000-1/1)#exit

Brocade_AS1(config)#esi iptv-service encapsulation isid

Brocade_AS1(config-esi-iptv-service)#isid 10000

Brocade_AS1(config-esi-iptv-service-isid-10000)#exit

Brocade_AS1(config)#esi iptv-carrier encapsulation bvlan

Brocade_AS1(config-esi-iptv-carrier)#vlan 10

Brocade_AS1(config-esi-iptv-carrier-vlan-10)#tagged ethernet 1/1

Brocade_AS1(config-esi-iptv-carrier-vlan-10)#esi-client iptv-service

Sample configuration on CS1

Brocade_CS1(config)#mmrp enable

Brocade_CS1(config)#mmrp include-vlan 10 20

Brocade_CS1(config)#int e 1/2 e 1/10 e 1/12 e 1/15

Brocade_CS1(config-mif-1/2, 1/10, 1/12, 1/15)#mmrp enable

PBB configuration MLX for B-VLAN 10

Brocade_CS1(config)# vlan 10

Brocade_CS1(config-vlan-10)#tag e 1/2 e 1/10 e 1/12 e 1/15

Brocade_CS1(config)#

PBB configuration on Metro for B-VLAN 10

Brocade_CS1(config)#interface e 1/2 e 1/10 e 1/12 e 1/15

Brocade_CS1(config-if-e10000-1/1)#port-type backbone-network

Brocade_CS1(config-if-e10000-1/1)#exit

Brocade_CS1(config)#esi iptv-carrier encapsulation bvlan

Brocade_CS1(config-esi-iptv-carrier)#vlan 10

Brocade_CS1(config-esi-iptv-carrier-vlan-10)#tagged e 1/2 e 1/10 e 1/12 e 1/15

MMRP is used with PBB for the registration and declaration of Multicast B-DA MAC.

Declaration of MAC

The declaration of the multicast MAC is done by the BEB. In the topology described above, the
declaration is sent if AS1 is

•

Brocade NetIron CER and Brocade NetIron CES

•

when an ISID ESI IPTV-service is added as client to the B-VLAN ESI IPTV-carrier

•

when MMRP is enabled on the port belonging to a B-VLAN with ISID clients associated

•

when a port enabled with MMRP is tagged to B-VLAN with ISID clients associated

•

Brocade MLX series and Brocade NetIron XMR

•

when B-VLAN 10 ISID 10000 endpoint is created in the VPLS instance

•

when MMRP is enabled on the port where B-VLAN and ISID is configured

When MMRP sends Join PDU on ports in the B-VLAN. The attribute declared here would be the
multicast flood MAC (011e.8300.2710).

Displaying the declared MAC on AS1

Brocade_AS1# show mmrp attributes

Port

Vlan

Mac-address

Registrar

Registrar

Applicant

State

Mgmt

State

----------------------------------------------------------------------------

1/1

10

011e.8300.2710 IN

Fixed

Quiet Active

Registration of MAC