Deployment scenarios and cli configuration, Configuration for ce devices – Brocade Multi-Service IronWare Switching Configuration Guide (Supporting R05.6.00) User Manual
Page 337

Multi-Service IronWare Switching Configuration Guide
307
53-1003036-02
802.1ag over PBB OAM
11
Sample Output:
CES-2#show cfm connectivity domain customer ma admin rmep-id 1
Output:
Domain: customer Level: 7
Maintenance association: admin VLAN VLAN/VPLS/VLL ID: 100 Priority: 7
CCM interval: 100ms
RMEP MAC PORT Oper Age CCM RDI
State Val Cnt
==== ========= ====== ===== ===== ======= ==========
1 0024.3863.7745 1/1 OK 8180 13 Y
Port Intf Intvl Seq
Status Status Error Error
====== ====== ===== =====
0 0 N N
Deployment Scenarios and CLI Configuration
NOTE
RDI is not supported for LINK MA.
Deployment Scenario 1 (Down MEPs on CEs and MIP on PE)
FIGURE 54
Deployment scenario 1
Configuration for CE Devices
Configuration for CE devices is the same as for 802.1ag over VLAN.
Configuring CE-1
VLAN configuration
Brocade(config)#vlan 10
Brocade(config-vlan-10)#tagged ethernet 1/1
CFM configuration:
1. To enable CFM, enter the following command:
Brocade(config)#cfm-enable