548

Multi-Service IronWare Switching Configuration Guide

53-1003036-02

ERP support for PBB (Brocade MLX series and Brocade NetIron XMR)

15

raps-default-mac

enable

!

Node-3 Configuration for Sub ring VLAN 100

!

vlan 100

tagged ethe 1/2

!

erp 200

right-interface vlan 100 ethe 1/2

raps-default-mac

sub-ring parent-ring-id 100

raps-propagate-tc

rpl vlan 100 ethe 1/2

enable

!

FIGURE 156

RAPS-propagate-tc configuration

A and B are end-points exchanging traffic, active path is as indicated by green line.

FIGURE 157

RAPS-propagate-tc topology change

When the link connecting Node-1 and Node-2 goes down, it results in topology change on the
sub-ring.

To restore the traffic between endpoints A and B, an FDB flush is performed on all sub-ring
nodes, interconnection nodes (Node-3 and Node-5) and Node-4.