Brocade Multi-Service IronWare Switching Configuration Guide (Supporting R05.6.00) User Manual

Page 932

Advertising
background image

902

Multi-Service IronWare Switching Configuration Guide

53-1003036-02

ACL-based Inbound sFlow

23

Table 119

shows the output information provided by the show sflow command.

TABLE 119

sFlow information

Field

Description

sFlow services

The feature state, which can be one of the following:

disabled

enabled

sFlow management VRF

Indication that sFlow is enabled to use the management VRF. Disabled
means that sFlow is using the non-management VRF instance.

sFlow management VRF name

Management VRF name, if the management VRF is enabled on sFlow.

sFlow agent IP address

The IP address that sFlow is using in the agent_address field of packets
sent to the collectors. Refer to

“Source address”

.

sFlow agent IPV6 address

The sFlow agent IPv6 address is unspecified by default. If configured, it
will correspond to the IP address on the configured interface.

sFlow source IP address

The sFlow source IP address corresponds to the IP address on the
configured interface. If an IP address is not configured on the interface,
then it will be unspecified. However, if the source interface is null0, then
it will be null0 on the interface.

sFlow source IPv6 address

The sFlow source IPv6 address that corresponds to the IP address on
the configured interface. If an IP address is not configured, then the
interface will be unspecified. However, if the interface is null0, then the
configured interface will be null0.

UDP

The sFlow source UDP port default is 8888.

Collector

The collector information. The following information is displayed for each
collector:

IP address

UDP port

If more than one collector is configured, the line above the collectors
indicates how many have been configured.

Polling interval

The port counter polling interval.

Configured default sampling rate

The configured global sampling rate. If you changed the global sampling
rate, the value you entered is shown here.

UDP packets exported

The number of sFlow export packets the device has sent.
NOTE: Each UDP packet can contain multiple samples.

sFlow samples collected

The number of sampled packets that have been sent to the collectors.

sFlow ports

The ports on which you enabled sFlow.

Global Sample Rate

The global sampling rate for the device.

Port Sampling Rate

The sampling rates of a port on which sFlow is enabled.

Hardware Sample Rate

The actual sampling rate. This is the same as the Global Sample Rate

Advertising