Erp commands, Assigning erp ids, Naming an ethernet ring node – Brocade Multi-Service IronWare Switching Configuration Guide (Supporting R05.6.00) User Manual

Page 561

Advertising
background image

Multi-Service IronWare Switching Configuration Guide

531

53-1003036-02

ERP commands

15

•

Enable the configuration

You must perform the following minimum configuration tasks for each non-RPL node:

•

Configure an ERP instance

•

Set the left and right interfaces

•

Configure the maintenance entity group end points (MEP) from each ERN, which can have a
role of RPL owner or non-RPL node, adjacent to switches not participating in the ERP
configuration

•

Enable the configuration

ERP commands

This section lists ERP configuration commands.

Assigning ERP IDs

You must assign an ERP ID. This ID number is used to:

•

Filter and clear statistics associated with a particular ERP ID

•

Delete the non-revertive mode in the case of an RPL owner

•

Clear WTR and WTB timers

The erp_id value is a number from 1 to 255.

Syntax: erp erp_id

For example, to assign the number 10 to the ERP, enter:

(config)# erp 10

Naming an Ethernet Ring Node

From within the ERP configuration shell, you can optionally name an ERN with a meaningful name.
The name must be 31 alphanumeric characters or fewer; and the name can use the “underscore”
and “dash” special characters.

Syntax: [no] name erp_name

For example, to assign the name “to_brocade1” to an ERN with ID number 10, enter:

Brocade(config)# erp 10

Brocade(config-erp-10)# name “to_brocade1”

Use the no command to remove the name.