Forced switch

15

Figure 141

shows the sequential order of events triggered as a result of an operator-initiated forced

switch command entered from ERN 4.

FIGURE 141

Single FS process--operator entered the forced switch command from ERN 4

RPL owner (ERN1)

Non-RPL node (ERN 2)

Non-RPL node (ERN 3)

Non-RPL node (ERN 4)

Idle

Idle

Idle

From the Idle state, ERN 4:
1

Processes the Forced
Switch command

2

Blocks the requested
port

3

Transmits R-APS (FS)

4

Unblocks the
non-requested port

5

Flushes the FDB

6

Enters the Forced
Switch (FS) state

From the Idle state, ERN 1:
1

Unblocks the RPL

2

Flushes the FDB for
first time

3

Forwards R-APS(FS)

4

Enters the FS state

From the Idle state, ERN 2:
1

Unblocks the port

2

Flushes the FDB for
the first time

3

Forwards R-APS(FS)

4

Enters the FS state

From the Idle state, ERN 3:
1

Unblocks the port

2

Flushes the FDB for the
first time

3

Forwards R-APS(FS)

4

Enters the FS state

From the FS state, ERN 1
forwards R-APS

From the FS state, ERN 2
forwards R-APS

From the FS state, ERN 3
forwards R-APS

From the FS state, ERN 4:
7. Transmits R-APS(FS)
8. Terminates the received
R-APS on the blocking port
9. Terminates its own
R-APS(FS)

All ERNs remain in FS state.