Show VLAN commands

8

Brocade#show vlan brief

Configured PORT-VLAN entries: 1

Maximum PORT-VLAN entries: 512

Default PORT-VLAN id: 1

VLAN Name Encap ESI Pri Ports

---- ---- ----- --- --- -----

10 [None] cvlan acme -

Syntax: show vlan brief

Displaying a single ESI

To display details of a single ESI, enter the following command from any level of the CLI.

Brocade#show esi acme

ESI Name Encap Number of Provider Provider Provider Client

Members ESI Encap VLAN ESIs

-------- ----- --------- -------- ----- -------- ------

acme cvlan 1 0

VLAN(s) at this ESI:

-------------------

VLAN Name Pri [L2 Protocols] Ports

10 [None] cvlan acme - NONE

Displaying all ESIs

Use the show esi command to display a list of all the ESIs configured in the system. This command
can be used at any level of the CLI.

Brocade(config)#show esi

ESI Name Encap Number of Provider Provider Provider Client

Members ESI Encap VLAN ESIs

-------- ----- --------- -------- ----- -------- ------

acme cvlan 1 0

Syntax: show esi name

Tag-type configuration

For the Brocade NetIron CES and Brocade NetIron CER, the following two VLAN tag-types are
allowed that can be configured globally:

tag1 applies to customer edge ports (CVLAN) by default.

tag2 applies to provider-network, backbone-edge, and backbone-network port types (SVLAN
and BVLAN) by default.