Displaying a single esi, Tag-type configuration, Displaying all esis – Brocade Multi-Service IronWare Switching Configuration Guide (Supporting R05.6.00) User Manual
Page 257

Multi-Service IronWare Switching Configuration Guide
227
53-1003036-02
Show VLAN commands
8
Brocade#show vlan brief
Configured PORT-VLAN entries: 1
Maximum PORT-VLAN entries: 512
Default PORT-VLAN id: 1
VLAN Name Encap ESI Pri Ports
---- ---- ----- --- --- -----
10 [None] cvlan acme -
Syntax: show vlan brief
Displaying a single ESI
To display details of a single ESI, enter the following command from any level of the CLI.
Brocade#show esi acme
ESI Name Encap Number of Provider Provider Provider Client
Members ESI Encap VLAN ESIs
-------- ----- --------- -------- ----- -------- ------
acme cvlan 1 0
VLAN(s) at this ESI:
-------------------
VLAN Name Pri [L2 Protocols] Ports
10 [None] cvlan acme - NONE
Displaying all ESIs
Use the show esi command to display a list of all the ESIs configured in the system. This command
can be used at any level of the CLI.
Brocade(config)#show esi
ESI Name Encap Number of Provider Provider Provider Client
Members ESI Encap VLAN ESIs
-------- ----- --------- -------- ----- -------- ------
acme cvlan 1 0
Syntax: show esi name
Tag-type configuration
For the Brocade NetIron CES and Brocade NetIron CER, the following two VLAN tag-types are
allowed that can be configured globally:
•
tag1 applies to customer edge ports (CVLAN) by default.
•
tag2 applies to provider-network, backbone-edge, and backbone-network port types (SVLAN
and BVLAN) by default.