802.1ag over PBB OAM

11

Configuration for PE Devices

Configuring PEB-1
The local VPLS configuration will be the same as shown in the previous deployment scenario. If the
local VPLS configuration is not done prior to configuring maintenance association, the MA
configuration is not allowed. Also, the port and vlan in the MEP configuration should exist in local
VPLS configuration prior to MEP configuration. Otherwise, it is not allowed. The port in the MEP
configuration can be either a tagged or untagged port already present in the local-VPLS
configuration.

CFM configuration steps for PEB-1

1. Enter the cfm-enable command to enable CFM.

Brocade(config)#cfm-enable

2. Create a maintenance domain with a specified name PROVIDER_1 and level 4.

Brocade(config-cfm)#domain-name PROVIDER_1 level 4

3. Create a maintenance association within a specified domain of pbb-vpls 20 with priority 3.

Brocade(config-cfm-md-PROVIDER_1)#ma-name ma_8 pbb-vpls 20 priority 3

4. Set the time interval between successive Continuity Check Messages (CCM). The default is

10-seconds.

Brocade(config-cfm-md-PROVIDER_1-ma-ma_8)#ccm-interval 10-second

5. Configure a MEP on port 1/1 and vlan 10.

Brocade(config-cfm-md-PROVIDER_1-ma-ma_8)#mep 6 up vlan 10 port ethe 1/1

A similar configuration will need to be done on PEB-3. MIP should be configured on PEB-5, PEB-6,
PCB-1, PCB-2, PCB-3, and PCB-4.

CFM configuration steps for PEB-5.

1. Enter the cfm-enable command to enable CFM.

Brocade(config)#cfm-enable

2. Create a maintenance domain with a specified name PROVIDER_1 and level 4.

Brocade(config-cfm)#domain-name PROVIDER_1 level 4

3. Create a maintenance association within a specified domain of pbb-vpls 20 with priority 3.

Brocade(config-cfm-md-PROVIDER_1)#ma-name ma_8 pbb-vpls 20 priority 3

4. Set the time interval between successive Continuity Check Messages (CCM). The default is

10-seconds.

Brocade(config-cfm-md-PROVIDER_1-ma-ma_8)#ccm-interval 10-second

To monitor the connectivity between PEB-1 and PEB-3, you can use the show cfm connectivity
command as mentioned in the previous scenario. Also, you can use either loopback or linktrace on
PEB-1 or PEB-3.