ERP over ESI VLAN (Brocade NetIron CES and Brocade NetIron CER)
15
The interconnection nodes play a vital role in traffic forwarding and should be aware of ERP
instances associated with each other within the node. In
, the DUT17 interconnection
node needs to be aware of Ring 1 being a sub-ring of the Ring 2 ERP instance. This association is
important as it is required to perform a FDB flush in Ring-2 on receiving R-APS (SF) messages from
Ring-1 .
Interconnection Rings with same VLANs
, where one B-VLAN span across multiple rings, the ring
mapping will still be maintained as it helps push the events from sub-rings to major ring.
The PB case will be also handled similarly.
FIGURE 147
ERP configuration with same VLAN
Sample configurations
PB ring node
FIGURE 148
PB ring node sample configuration
PE-2 Configuration with S-VLAN 200:
!
esi svlan encapsulation svlan
vlan 200
tagged ethe 1/1 ethe 1/2
!
erp 200
left-interface esi svlan vlan 200 ethe 1/1
right-interface esi svlan vlan 200 ethe 1/2
rpl-owner
sub-ring
rpl esi svlan vlan 200 ethe 1/2