Use case 6: core rstp, Core rstp, Figure 103 – Brocade Multi-Service IronWare Switching Configuration Guide (Supporting R05.6.00) User Manual

Page 492

Advertising
background image

462

Multi-Service IronWare Switching Configuration Guide

53-1003036-02

RSTP support for PB and PBB

13

Configuring CE-1
C-VLAN Configuration

Configure a regular Layer 2 VLAN with 400 (C-VLAN) and add port 1/1 to it.

Brocade_CE-1(config)#vlan 400

Brocade_CE-1(config-vlan-400)#tagged ethernet 1/1

Configuring CE-2
C-VLAN Configuration

Configure a regular Layer 2 VLAN with 400 (C-VLAN) and add port 1/4 to it.

Brocade_CE-2(config)#vlan 400

Brocade_CE-2(config-vlan-400)#tagged ethernet 1/4

Configuring RSTP on CE-1 and CE-2
RSTP Configuration

Brocade_CE-1(config)#vlan 400

Brocade_CE-1(config-vlan-400)#rstp

Use case 6: Core RSTP

The following deployment scenario is a case where RSTP is deployed for a single B-VLAN in a PBB
network. In CS-1 and CS-2 a regular VLAN 100 is configured as B-VLAN which carries the traffic to
the PBB core network. AS-1 and AS-2 have a regular VLAN and VPLS VLAN 100 which carries PBB
traffic towards the B-VLAN. CS-1 is configured as the ROOT Bridge and RSTP is running over regular
VLAN 100 in CS-1 and CS-2. In AS-1 and AS-2 RSTP runs over the regular VLAN 100 corresponds to
the VPLS VLAN B-VLAN 100.

The following discussion describes how to configure the nodes in the topology.

FIGURE 103

Core RSTP in PBB network

 

CS‐1

AS‐2

AS‐1

CS‐2

ES‐2 

ES‐1 

Core RSTP 

1/1

1/2

1/1

1/2

1/2

1/1

1/1

1/2

1/10 

1/10 

1/10 

1/10 

1/3

1/3

 (B‐ VLAN 100)

Advertising