Checking cooling system, Checking cap for filler neck, Checking coolant system for leaks – BMW K 1100 LT/RS User Manual

Page 152

Advertising
background image

17.10

Checking cooling system

Checking cap for filler neck

Remove fuel tank.

Connect adapter (1), BMW No. 17 0 003, to
pump, BMW No. 17 0 500.

Screw cap onto screw coupling (2),
BMW No. 17 0 004, and connect to pump.

Pressure test cap.

Pressure relief valve opens at

.. 1.5 bar (21.756 psi)

Checking coolant system for leaks

Screw pump, BMW No. 17 0 500, with adapter
and screw coupling to filler neck.

Apply pressure to cooling system; pressure must
remain unchanged for at least 10 minutes.

Test pressure

.............................. 1 bar (14.504 psi)

Install in the reverse order of removal.

17 0 004

LT170090

17 0 003

17 0 500

Advertising