X23JR0620113
O
NLY PERFORM THE ROTATION MANOEUVRE
‑
Once the machine is aligned, release the key, remove it, put it back in its original position
and close the electric components compartment.
Note.: In case of machine with variable stabilization area the by‑pass of the safety measures
does not allow to go out the working area related to the stabilization configuration.
B)
Movement of the under‑carriage with the machine not aligned:
‑
Open the electric components compartment;
‑
Position the emergency on the electric components box,
withdrawing it from the machine key ring, where it is
lead‑sealed (see photo);
‑
Activate the emergency key by turning it in a
clockwise direction and holding it in position
(see sticker);
The safety devices BY‑PASS icon will appear on
the remote control display.
O
PERATION ONLY ALLOWED TO GO TO A CONDITION SUITABLE TO CARRY OUT THE PROCEDURE
INDICATED IN POINT
A. A